Y-cable for parallel connection of two terminal devices to the RS-232 interface on the scale, e.g. signal lamp and printer
TECHNICAL DATA
Dimension (W×D×H) | 50×300×50 mm |
Cable length | 1,5 m |
Net weight approx. | 0,15 kg |
Here you will find any scale for professional applications in industry, trade und retail. Regardless of where your business weighs in - you'll find the right scale at Scales and Measuring.
Scales and Machinery for catering and commercial food services
In the "Medical scales and measuring devices" category, we offer a wide range of high-quality and precise medical measuring instruments for clinics, doctor's practices, care facilities and veterinarians. These specialized devices are designed to carry out precise measurements and weight determinations in a medical context and thus contribute to the precise diagnosis, therapy and care of patients.
Our selection includes different types of medical scales that meet the specific requirements of different medical disciplines. These include body scales for determining patient weight, baby scales for precisely monitoring the growth of newborns, and animal scales for veterinary applications. These scales are carefully calibrated to ensure high accuracy and reliability.
In addition to scales, we offer a variety of other medical devices, including blood pressure monitors, pulse and oxygen monitors, and body temperature monitors. These instruments enable comprehensive monitoring of patients' vital parameters and thus support preventive medicine and the early detection of health problems.
Our products come from renowned manufacturers who adhere to the highest quality standards. They are ergonomically designed and easy to use, ensuring smooth integration into clinical or veterinary workflow. In addition, many of our medical devices are equipped with modern interfaces that enable seamless integration into digital health records and other information systems.
Trust our medical scales and devices to take precise measurements and create a reliable basis for medical decisions. With our extensive range, we support healthcare providers in ensuring optimal patient care and increasing the efficiency of their work processes.
For centuries now, weight pieces have been used in scales for weighing procedures. This original purpose has now almost disappeared. Today, weights are used almost exclusively for adjusting and testing = calibration of electronic balances. They are now named “test weights” as this is their contemporary purpose.
Adjusting a balance means that you are intervening in the weighing system, to make sure that the display is set to show the correct nominal value.
With calibration on the other hand, there is no intervention, you are testing whether the display is correct and documenting any deviation.
The internationally valid OIML norm R111:2004 classifies test weights hierarchically in accuracy classes, where E1 is the most accurate and M3 is the least accurate weight class. With KERN you get the whole test weight range in all OIML accuracy classes E1, E2, F1, F2, M1, M2, M3.
As the test weight only becomes an ISO 9000ff-compliant test instrument when its accuracy has been proven, we offer the appropriate DAkkS Calibration certificate or verification certificate (in connection with a box) for all KERN test weights. For further details see chapter DAkkS Calibration Service.
We offers you the appropriate test weight package for your balance, consisting of the test weight, box and DAkkS-calibration certificate, as proof of its accuracy. The best prerequisite for a correct adjustment or checking of your scales.
Classes of accuracy of test weights E, F, M and their general relation to the types of balances:
Test weights for customers who require a high degree of accuracy for the most demanding applications. For high-resolution balances with d > 1,000,000 Use recommended with DAkkS calibration certificate only.
Most accurate test weights for high resolution analytical balances of verification class I ≥ 100,000 e
Test weights for analytical balances/precision balances for verification class I/II ≤ 100,000 e
Test weights for precision balances of verification class II ≤ 30,000 e
Test weights for industrial and commercial scales of verification class III ≤ 10,000 e
The appropriate test weight for your new KERN balance can also be found directly in the accessories of the balance in our webshop.
To protect your test weights we can offer you an appropriate weight case. If there are no legal or normative specifications, then you have the choice between plastic, aluminium protected or wood. The available weight cases are shown as a symbol in the test weight tables on the following pages. This way you have all the materials, versions, sizes and prices at a glance, listed in a concise way.
A balance can never be more accurate than the test weight that is used to adjust it, it all depends on its tolerance. The accuracy of the test weight should correspond to the readout [d] of the balance, or rather be more precise.
Nominal weight value is shown in adjust mode “CAL” in the balance display. Given a choice, the heaviest weight is the most suitable for accurate measurement.
Once accuracy and nominal weight value are specified, the suitable test weight is selected according to the tolerances “Tol” of the indi vidual accuracy classes E2 – M3, see column “Tol ± mg” at the respective weight.
Balance with weighing range [Max] 2000 g = 2 kg and readout [d] = 0,01 g = 10 mg
Exception: analytical balances (readout [d] ≤ 0,1 mg): E1 test weights are recommended. Depending on the safety requirements, E2 test weights with a DAkkS calibration certificate will also be sufficient.
The key points from the OIML norm R111:2004 OIML (Organisation Internationale de Métrologie Légale) has established the exact metrological requirements for weights in verified applications in approx. 100 states all over the world. The OIML recommendation R111 (2004 Edition) for weights relates to sizes 1 mg – 5000 kg. Statements are made on the accuracy, materials, geometric shape, marking and storage of the weights.
The error limit classes are in fixed hierarchical levels in the proportion of 1:3, where E1 is the most accurate and M3 is the least accurate weight class. When testing weights with other weights, the correct test class is the next highest class.
Error limit classes (= tolerances)
The values given in the table below (tolerances ± ... mg) are the respective permitted fabrication tolerances. They are to be equal to the measuring uncertainty of the weight, if no DAkkS calibration certificate is available.
The problem is the air buoyancy, which makes the weight appear lighter. In order to avoid this “distortion” in daily use, all weights are adjusted to the unit specifications as given in R111, e.g. it is accepted that: material density of the weights is 8000 kg/m3, air density is 1.2 kg/m3 and measuring temperature is 20 °C.
Our test weights: Unless otherwise specified, they conform to OIML R111:2004 in every detail.
and much more
Measurement technology for industry, laboratories and quality assurance
Accessories
Offers and discontinued models
Y-cable for parallel connection of two terminal devices to the RS-232 interface on the scale, e.g. signal lamp and printer
Dimension (W×D×H) | 50×300×50 mm |
Cable length | 1,5 m |
Net weight approx. | 0,15 kg |
Three-colour LED, red, green, yellow
Suitable for bench scale KERN GAB-N, counting scale KERN CPB, platform scale KERN IFB, drive-through scale KERN NFB and display device KERN KFB-TM (on request: floor scale KERN BFB and pallet scale KERN UFB)
Overall dimensions WxDxH 100x180x300 mm
Protective working cover over keyboard and housing standard for FOB-NS
scope of delivery: 5 pcs
Protective working cover
scope of delivery: 5 items
Suitable for all models -NL and -LM
Suitable for Floor scales KERN BFB and KERN BFS, counting scale KERN CFS,bench scale KERN GAB-N, platform scale KERN IFB, Display devices KERN KFB-TM and KERN KFN-TM, drive-through scale KERN NFB, precision balance KERN PFB, Pallet scales KERN UFB and KERN UFN and Weighing beams dimensions KERN UFA
Protective working cover for KERN CXB
scope of delivery: 5 pcs
DE-A11N Mount to fasten the display device to the platform for Platform scales KERN DE-D and KERN DS
Dimensions (WxDxH): 200mm x 100mm x 40mm
Cable length | 1,8 m |
Plug-in power supply type | Power adapter |
Input voltage power supply / power [Max] | 100 V - 240 V, 50 / 60 Hz |
Input voltage device / power [Max] | 15 V, 500 mA |
Material | plastic |
MWS-A01 Stand to elevate display device for KERN MWS and EOB
KERN IXS-A03 Stand to elevate display device, height 400 mm
KERN IXS-A02 Stand to elevate display device, height 600 mm
Mains adapter standard EURO/US/AUS/UK/CH
Input voltage power supply / power [Max] 100 V - 240 V
Input voltage device / power [Max] 12 V, 500 mA
suitable for models: KERN MWS, KERN MPS, KERN MCB
High speed data transfer software for force-time-measurements
Pressure disc out of aluminium, thickness 10 mm, for compression tests up to 5 kN, ø 110 mm, outer thread: M12
Material: Aluminium
Scope of delivery: 1 piece
SAUTER 287-A01 Bracket for spring balance till 1000g/10N
SAUTER 287-A02 Hook for spring balances 10-1000 g
Calibration foils for increased measuring accuracy (covers the range from 20 up to 2000 µm, with ˂ 3 % tolerance)
ATE 01 Sensor, Type F for SAUTER Digital coating thickness gauge
Type F: Coatings on steel and iron
SAUTER ATE 02 Sensor Type N for coating thickness gauges
Type N: measuring Insulating coatings on non-magnetic metals
SAUTER ATC-01 Data transmission software for SAUTER TC, TE, TF and TG (interface cable included)