List of products by brand SAUTER
Active filters
- Availability: In stock
Mechanical force measurement with quality spring for long service life
TECHNICAL DATA
Measuring range force [Max] (N) | 1 N |
Readability force [d] (N) | 0,01 N; 0,05 N |
Tolerance (% of [Max]) | 0,3% |
Load support (tensile force) | Hook |
Length unloaded (l [Min]) | 230 mm |
Length loaded (l [Max]) | 335 mm |
Housing diameter (Ø) | 12,2 mm |
Dimensions completely mounted (W×D×H) | 230×12,2×12,2 mm |
Material housing | plastic |
Tensile/compressive force [Max] | 5 kN |
Maximum clamp width | 50 mm |
Clamping width | 15 mm |
Material | aluminium |
Net weight | 1,3 kg |
Mounting - force dissipation | Threaded hole M6, External thread M12 |
Delivery date on request
Practical measuring device for measuring the thickness of layers for daily use
TECHNICAL DATA
Measuring range coating thickness [d] (µm) | 100 µm; 1000 µm |
Readability coating thickness [d] (µm) | 0,1 µm; 1 µm |
Tolerance (% of [Max]) | 3% |
Units | µm, inch (mil) |
Coating thickness gauge sensor type | FE |
Test object thickness coating | Non-magnetic coatings on iron, steel, Type F |
Battery | 4×1.5 V AA |
Increase in measurement accuracy possible | |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 161×69×32 mm |
Cable length | 1 m |
Sensor placement position | external |
Tensile/compressive force [Max] | 10 kN |
Maximum clamp width | 10 mm |
Clamping width | 8 mm |
Material | steel |
Net weight | 3 kg |
Mounting - force dissipation | Threaded hole M6, External thread M12 |
Dimensions completely mounted (W×D×H) | 134×60×40 mm |
Calibration foils for increased measuring accuracy (covers the range from 20 up to 2000 µm, with ˂ 3 % tolerance)
ATE 01 Sensor, Type F for SAUTER Digital coating thickness gauge
Type F: Coatings on steel and iron
Practical measuring device for measuring the thickness of layers for daily use
TECHNICAL DATA
Measuring range coating thickness [d] (µm) | 100 µm; 1000 µm |
Readability coating thickness [d] (µm) | 0,1 µm; 1 µm |
Tolerance (% of [Max]) | 3% |
Units | µm, inch (mil) |
Coating thickness gauge sensor type | FE, NFE |
Test object thickness coating | Non-magnetic coatings on iron, steel, Type F, Coatings on non-magnetic metals, type N |
Battery | 4×1.5 V AA |
Increase in measurement accuracy possible | |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 161×69×32 mm |
Cable length | 1 m |
Sensor placement position | external |
Ergonomic design and external measuring head for highest ease of use
TECHNICAL DATA
Measuring range coating thickness [d] (µm) | 100 µm; 1250 µm |
Readability coating thickness [d] (µm) | 0,1 µm; 1 µm |
Tolerance (% of [Max]) | 3% |
Units | µm, inch (mil) |
Coating thickness gauge sensor type | FE |
Test object thickness coating | Non-magnetic coatings on iron, steel, Type F |
Battery | 4×1.5 V AAA |
Increase in measurement accuracy possible | |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 131×65×28 mm |
Sensor placement position | external |
Premium coating thickness gauge for paint layer, lacquer layer etc.
TECHNICAL DATA
Measuring range coating thickness [d] (µm) | 100 µm; 1250 µm |
Readability coating thickness [d] (µm) | 0,1 µm; 1 µm |
Tolerance (% of [Max]) | 3% |
Units | µm, inch (mil) |
Coating thickness gauge sensor type | FE, NFE |
Test object thickness coating | Non-magnetic coatings on iron, steel, Type F, Coatings on non-magnetic metals, type N |
Battery | 2×1.5 V AAA |
Memory function | |
Statistic function | |
Increase in measurement accuracy possible | |
Continuous capture possible | |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 130×64×32 mm |
Cable length | 1 m |
Sensor placement position | external |
6-wire connection: 2 additional wires to maintain a constant voltage supply at the load cell when used with proper instrumentation. Use specially when long wires and wide temperature range
- Nickel plated alloy steel IP67 (acc. to EN 60529) “S” type load cell
- Force measuring compatible
- Tension and compression applications
- RoHS conform
- Suitable for hanging, hopper and other weighing devices
- Suitable for testing facilities and test stands
- Accuracy OIML R60 C3
fits for digital coating thickness gauge TG 1250-0.1FN
magnetic and non magnetic
- External sensor, 7 MHz, Ø 6 mm
- For thin test materials: measuring range (steel) 0,75 - 80 mm
- Accuracy in accordance with OIML R60 C3
- protection against dust and water splashes IP65 (in accordance with EN 60529)
- Aluminium alloy, anodized
- Suitable for price-computing scales, bench scales, platform scales, etc.
- Maximum platform size 100–300 kg: 400×400 mm
- Maximum platform size 400–500 kg: 450×450 mm
- Nominal sensitivity: 2 mV/V
- Note: Version in accordance with OIML R60 C4 or C5 on request
Ultrasound contact gel, approx. 60 ml
Price 100 ml = 50,00 €
Reliable material thickness gauge for daily use
TB 200-0.1US-RED Can only analyse these materials: cast iron, aluminium, copper, brass, zinc, quartz glass, polyehylene, PVC, grey cast iron, nodular cast iron, steel
TECHNICAL DATA
Material thickness pulse-echo [Max] (mm) | 200 mm |
Material thickness pulse-echo [Min] (mm) | 1,5 mm |
Measuring range pulse-echo | 1,5 mm – 200 mm |
Measuring range echo-echo | – |
Readability material thickness [d] (mm) | 0,1 mm |
Tolerance (% of [Max]) | 0,5% |
Units | mm, inch |
Speed of sound [Max] (m/s) | 9999 m/s |
Speed of sound [Min] (m/s) | 500 m/s |
Speed of sound | 500 m/s – 9999 m/s |
Measuring head measuring frequency | 5 MHz |
Battery | 4×1.5 V AA |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 161×68×32 mm |
Cable length | 0,9 m |
Ultrasonic thickness gauge with external sensor
Material thickness pulse-echo [Max] (mm) | 225 mm |
Material thickness pulse-echo [Min] (mm) | 1,2 mm |
Measuring range pulse-echo | 1,2 mm – 225 mm |
Measuring range echo-echo | – |
Readability material thickness [d] (mm) | 0,1 mm |
Tolerance (% of [Max]) | 0,5% |
Units | mm, inch |
Speed of sound [Max] (m/s) | 9999 m/s |
Speed of sound [Min] (m/s) | 1000 m/s |
Speed of sound | 1000 m/s – 9999 m/s |
Measuring head measuring frequency | 5 MHz |
Battery | 4×1.5 V AAA |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 30×65×120 mm |
Cable length | 0,9 m |
External sensor, 5 MHz, Ø 10 mm, transducer at an angle of 90°
- Ideal for transferring measuring data from the internal data memory of the measuring instrument to Microsoft Excel®
- Suitable for Coating thickness gauges SAUTER TC, SAUTER TE, SAUTER TF, SAUTER TG
- Hardness testing device SAUTER HD
- Sound level meter SAUTER SU
- Ultra-sound material thickness measuring device SAUTER TD-US, TN-US
- Compatible with following operating systems: Microsoft Windows 7, 8.1, 10®
- interface cable included
- External sensor, 2,5 MHz, Ø 14 mm
- for thick samples, in particular cast iron with rough upper surfaces: measuring range (steel) 3 - 300 mm
Precise, mechanical force gauge in robust aluminium housing with Newton readout
Technical Data
Measuring range force [Max] (N) | 1 N |
Readability force [d] (N) | 0,01 N |
Tolerance (% of [Max]) | 0,3% |
Load support (tensile force) | Hook |
Length unloaded (l [Min]) | 225 mm |
Length loaded (l [Max]) | 305 mm |
Housing diameter (Ø) | 12 mm |
Dimensions completely mounted (W×D×H) | 225×12×12 mm |
Material housing | aluminium |