Prices drop
Immersion proof check weigher in a sturdy stainless steel housing. The IP68 version is also suitable for use in damp rooms and for frequent use in industry and gastronomy.
Robust check weigher in a sturdy stainless steel housing. The IP65 version is also suitable for use in damp rooms and for frequent use in industry and gastronomy. The graduation of the stainless steel scale can be selected as required on the divisions 0.1, / 0.2 / 0.5 / 1 g, depending on the application. The well-lit display on the front and back with particularly large digits makes it easy to read the results.
Robust check weigher in a sturdy stainless steel housing. The IP65 version is also suitable for use in damp rooms and for frequent use in industry and gastronomy. The graduation of the stainless steel scale can be selected as required on the divisions 0.1, / 0.2 / 0.5 / 1 g, depending on the application. The well-lit display on the front and back with particularly large digits makes it easy to read the results.
EMB-A02 Stainless steel weighing plate (Ø 105 mm), for KERN EMB 200-2, 600-2
Stand to elevate display device, height of stand approx. 250 mm
Temperature calibration set for Moisture analyser KERN DBS
Temperature calibration set consists of measuring sensor and display device
Technical Data
| Material | plastic + metal |
| Material housing | ABS plastic |
| Cable length | 1 m |
| Auto-off interval(s) in battery mode/rechargeable battery mode | 10 min |
| Battery / accumulator type | Alkali(-Manganese) |
| Battery capacity | 1.200 mAh |
| Battery voltage | 4,5 V |
| Rechargeable battery operating time - backlight off | 80 h |
| Temperature [Min] (°C) | -70 °C |
| Temperature [Max] (°C) | 400 °C |
| Readability temperature [d] (°C) | 0,1 °C |
| Units | °C |
| Net weight approx. | 0,15 kg |
Tensile force gauge with integrated display
Technical Data KERN HFA 10kN
| Measuring range [Max] | 10 kN |
| Readability [d] | 5 N |
| Units | kg, lb, N |
| Reproducibility | 5 N |
| Linearity | ± 10 N |
| Ambient temperature | 5 °C – 35 °C |
| Display type | LCD |
| Display digit height | 23 mm |
| Material housing | steel |
| Tolerance weighing | |
| Net weight approx. | 6 kg |
| Housing dimensions (W×D×H) | 90×75×275 mm |
Tensile force gauge with integrated display
Technical Data KERN HFA 1kN
| Measuring range [Max] | 1 kN |
| Readability [d] | 0,5 N |
| Units | kg, lb, N |
| Reproducibility | 0,5 N |
| Linearity | ± 1 N |
| Ambient temperature | 5 °C – 35 °C |
| Display type | LCD |
| Display digit height | 23 mm |
| Material housing | aluminium |
| Tolerance weighing | |
| Net weight approx. | 1,8 kg |
| Housing dimensions (W×D×H) | 90×62×255 mm |
Tensile force gauge with integrated display
Technical Data KERN HFA 3kN
| Measuring range [Max] | 3 kN |
| Readability [d] | 1 N |
| Units | kg, lb, N |
| Reproducibility | 1 N |
| Linearity | ± 2 N |
| Ambient temperature | 5 °C – 35 °C |
| Display type | LCD |
| Display digit height | 23 mm |
| Material housing | aluminium |
| Tolerance weighing | |
| Net weight approx. | 2 kg |
| Housing dimensions (W×D×H) | 90×65×255 mm |
Tensile force gauge with integrated display
Technical Data KERN HFA 5kN
| Measuring range [Max] | 5 kN |
| Readability [d] | 2 N |
| Units | kg, lb, N |
| Reproducibility | 2 N |
| Linearity | ± 4 N |
| Ambient temperature | 5 °C – 35 °C |
| Display type | LCD |
| Display digit height | 23 mm |
| Material housing | steel |
| Tolerance weighing | |
| Net weight approx. | 4 kg |
| Housing dimensions (W×D×H) | 90×65×255 mm |
Tensile force gauge with integrated display
Technical Data KERN HFA 600N
| Measuring range [Max] | 600 N |
| Readability [d] | 0,2 N |
| Units | kg, lb, N |
| Reproducibility | 0,2 N |
| Linearity | ± 0,6 N |
| Ambient temperature | 5 °C – 35 °C |
| Display type | LCD |
| Display digit height | 23 mm |
| Material housing | aluminium |
| Tolerance weighing | |
| Net weight approx. | 1,8 kg |
| Housing dimensions (W×D×H) | 90×62×255 mm |
Test bench for round, flat objects for use with Ultrasound hardness testing device SAUTER HO-M
- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
Ideal for torque testing of bottles and other packaging with screw tops
Measuring System
Measuring range torque [Max] 1 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 10 Nm
characteristic value - nominal 1,2 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 10 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 100 Nm
characteristic value - nominal 1,9 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg