Prices drop
Quick-display precision balance with user-friendly concept of operation mode - now also with checkweighing function
Technical Data KERN PFB 200-3
| Weighing capacity [Max] | 200 g |
| Readability [d] | 1 mg |
| Units | kg, g, t, gn, dwt, tl (Tw), tl (HK), ozt, tl (Singap, Malays), ct, mo, lb, oz, ffa, tol, m |
| Linearity | ± 4 mg |
| Reproducibility | 2 mg |
| Stabilization time | 2 s |
| Tolerance weighing | |
| Interfaces | RS-232 standard, Bluetooth BTC (v2.0) (optional, factory), Bluetooth BLE (v4.0) (optional, factory) |
| Adjustment options | Adjusting with external weight |
| Recommended adjusting weight | 200 g (F1) |
| Ambient temperature | 15 °C – 30 °C |
| Dimensions weighing surface (Ø) | 80 mm |
| Material draught shield | glass |
| Material housing | plastic |
| Dimension housing (W×D×H) | 210×315×90 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 1,2 kg |
Quick-display precision balance with user-friendly concept of operation mode - now also with checkweighing function
Technical Data KERN PFB 300-3
| Weighing capacity [Max] | 300 g |
| Readability [d] | 1 mg |
| Units | kg, g, t, gn, dwt, tl (Tw), tl (HK), ozt, tl (Singap, Malays), ct, mo, lb, oz, ffa, tol, m |
| Linearity | ± 5 mg |
| Reproducibility | 3 mg |
| Stabilization time | 2 s |
| Tolerance weighing | |
| Interfaces | RS-232 standard, Bluetooth BTC (v2.0) (optional, factory), Bluetooth BLE (v4.0) (optional, factory) |
| Adjustment options | Adjusting with external weight |
| Recommended adjusting weight | 300 g (F1) |
| Ambient temperature | 15 °C – 30 °C |
| Dimensions weighing surface (Ø) | 80 mm |
| Material draught shield | glass |
| Material housing | plastic |
| Dimension housing (W×D×H) | 210×315×90 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 1,2 kg |
![]()
Technical Data KERN PFB 600-1M
| Weighing capacity [Max] | 600 g |
| Readability [d] | 0,1 g |
| Units | kg, g, t, gn, dwt, tl, ozt, ct, mo, lb, oz, ffa, tol, m |
| Linearity | ± 0,2 g |
| Reproducibility | 0,1 g |
| Stabilization time | 2 s |
| Interfaces | RS-232 standard |
| Adjustment options | Adjusting with external weight |
| Recommended adjusting weight | 600 g (F1) |
| Ambient temperature | 15 °C – 30 °C |
| Dimensions weighing surface (Ø) | 120 mm |
| Material draught shield | glass |
| Material housing | plastic |
| Material weighing plate | stainless steel |
| Net weight approx. | 2 kg |
Quick-display precision balance with user-friendly concept of operation mode - now also with checkweighing function
Technical Data KERN PFB 600-3
| Weighing capacity [Max] | 600 g |
| Readability [d] | 1 mg |
| Units | kg, g, t, gn, dwt, tl (Tw), tl (HK), ozt, tl (Singap, Malays), ct, mo, lb, oz, ffa, tol, m |
| Linearity | ± 5 mg |
| Reproducibility | 5 mg |
| Stabilization time | 6 s |
| Tolerance weighing | |
| Interfaces | RS-232 standard, Bluetooth BTC (v2.0) (optional, factory), Bluetooth BLE (v4.0) (optional, factory) |
| Adjustment options | Adjusting with external weight |
| Recommended adjusting weight | 600 g (E2) |
| Ambient temperature | 15 °C – 30 °C |
| Dimensions weighing surface (Ø) | 120 mm |
| Material draught shield | glass |
| Material housing | plastic |
| Dimension housing (W×D×H) | 210×315×90 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 1,2 kg |
Quick-display precision balance with user-friendly concept of operation mode - now also with checkweighing function
Technical Data KERN PFB 6000-2
| Weighing capacity [Max] | 6000 g |
| Readability [d] | 0,01 g |
| Units | kg, g, t, gn, dwt, tl (Tw), tl (HK), ozt, tl (SN), ct, mo, lb, oz, ffa, tol, m |
| Linearity | ± 0,07 g |
| Reproducibility | 0,05 g |
| Stabilization time | 6 s |
| Tolerance weighing | |
| Interfaces | RS-232 standard, Bluetooth BTC (v2.0) (optional, factory), Bluetooth BLE (v4.0) (optional, factory) |
| Adjustment options | Adjusting with external weight |
| Recommended adjusting weight | 6 kg (E2) |
| Ambient temperature | 15 °C – 30 °C |
| Dimensions weighing surface (W×D) | 190×180 mm |
| Material housing | plastic |
| Dimension housing (W×D×H) | 210×315×90 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 1,8 kg |
![]()
Precision balance with robust tuning fork weighing system
Technical Data
| Weighing capacity [Max] | 12000 g |
| Readability [d] | 0,1 g |
| Verification scale interval [e] | 1 g |
| Units | g, dwt, tl, mo, lb, oz, tol |
| Conformity assessment possible ex works | |
| Minimum weight [Min] | 5 g |
| Linearity | ± 0,2 g |
| Reproducibility | 0,1 g |
| Stabilization time | 3 s |
| USP Minimum weight of sample (k = 2, U = 0.1%) | 200 g |
| Interfaces | RS-232 standard |
| Adjustment options | Internal calibration (automatic) |
| Ambient temperature | 5 °C – 40 °C |
| Dimensions weighing surface (W×D) | 190×190 mm |
| Material housing | plastic |
| Dimension housing (W×D×H) | 196×293×89 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 3,8 kg |
![]()
![]()
Precision balance with internal adjustment and robust tuning fork weighing system
TECHNICAL DATA
| Weighing capacity [Max] | 3200 g |
| Readability [d] | 0,01 g |
| Verification scale interval [e] | 0,1 g |
| Conformity assessment possible ex works | |
| Minimum weight [Min] | 0,5 g |
| Linearity | ± 0,02 g |
| Reproducibility | 0,01 g |
| Stabilization time | 3 s |
| USP Minimum weight of sample (k = 2, U = 0.1%) | 20 g |
| Interfaces | RS-232 standard |
| Adjustment options | Internal calibration (automatic) |
| Ambient temperature | 5 °C – 40 °C |
| Dimensions weighing surface (W×D) | 190×190 mm |
| Material housing | plastic |
| Dimension housing (W×D×H) | 196×293×89 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 3,6 kg |
![]()
Precision balance for laboratory with robust tuning fork weighing system
| Weighing capacity [Max] | 620 g |
| Readability [d] | 1 mg |
| Verification scale interval [e] | 0,01 g |
| Units | g, gn, dwt, tl, ct, mo, lb, oz, tol |
| Conformity assessment possible ex works | |
| Minimum weight [Min] | 0,02 g |
| Linearity | ± 4 mg |
| Reproducibility | 1 mg |
| Stabilization time | 3 s |
| USP Minimum weight of sample (k = 2, U = 0.1%) | 2 g |
| Interfaces | RS-232 standard |
| Adjustment options | Internal calibration (automatic) |
| Ambient temperature | 5 °C – 40 °C |
| Dimensions weighing surface (Ø) | 140 mm |
| Material draught shield | glass |
| Material housing | plastic |
| Dimension housing (W×D×H) | 196×293×266 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 4,2 kg |
High-resolution precision balance made of stainless steel with IP protection
Technical Data
| Weighing capacity [Max] | 3200 g |
| Readability [d] | 0,1 g |
| Units | kg, g, gn, dwt, tl (Tw), tl (HK), ozt, tl (Singap, Malays), ct, mo, lb, oz, tol |
| Linearity | ± 0,1 g |
| Reproducibility | 0,1 g |
| Stabilization time | 3 s |
| USP Minimum weight of sample (k = 2, U = 0.1%) | 200 g |
| Interfaces | RS-232 standard |
| Adjustment options | Adjusting with external weight |
| Recommended adjusting weight | 3 kg (F1) |
| Ambient temperature | 10 °C – 30 °C |
| Dimensions weighing surface (W×D) | 190×190 mm |
| Material housing | stainless steel |
| Dimension housing (W×D×H) | 310×205×85 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 3,0 kg |
High-resolution precision balance made of stainless steel with IP protection
| Weighing capacity [Max] | 820 g |
| Readability [d] | 0,01 g |
| Units | kg, g, gn, dwt, tl (Tw), tl (HK), ozt, tl (Singap, Malays), ct, mo, lb, oz, tol |
| Linearity | ± 0,01 g |
| Reproducibility | 0,01 g |
| Stabilization time | 3 s |
| USP Minimum weight of sample (k = 2, U = 0.1%) | 20 g |
| Interfaces | RS-232 standard |
| Adjustment options | Adjusting with external weight |
| Recommended adjusting weight | 200 g (F1); 500 g (F1) |
| Ambient temperature | 10 °C – 30 °C |
| Dimensions weighing surface (Ø) | 140 mm |
| Material housing | stainless steel |
| Dimension housing (W×D×H) | 310×205×85 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 3,0 kg |
High-resolution precision balance made of stainless steel with IP protection
TECHNICAL DATA
| Weighing capacity [Max] | 8200 g |
| Readability [d] | 0,1 g |
| Units | kg, g, gn, dwt, tl (Tw), tl (HK), ozt, tl (Singap, Malays), ct, mo, lb, oz, tol |
| Linearity | ± 0,1 g |
| Reproducibility | 0,1 g |
| Stabilization time | 3 s |
| USP Minimum weight of sample (k = 2, U = 0.1%) | 200 g |
| Interfaces | RS-232 standard |
| Adjustment options | Adjusting with external weight |
| Recommended adjusting weight | 2 kg (F1); 5 kg (F1) |
| Ambient temperature | 10 °C – 30 °C |
| Dimensions weighing surface (W×D) | 190×190 mm |
| Material housing | stainless steel |
| Dimension housing (W×D×H) | 310×205×85 mm |
| Material weighing plate | stainless steel |
| Net weight approx. | 3,0 kg |
Rechargeable battery pack internal suitable for models KERN MCN, MPN, MWN
Sale only in conjunction with scale, not individual sale!
High-precision moisture analyzer for demanding analyses
Technical Data
| Weighing capacity [Max] | 120 g |
| Readability [d] | 1 mg |
| Weighing system | Force compensation |
| Sample – Moisture content | 0,01% - 100% |
| Sample – Dry content | 100% - 0,01% |
| Temperature range (in steps up to) | 30 °C - 175 °C (1 °C) |
| Stabilization time | 3 s |
| Units | g, % Humidity, % Dry mass, % ATRO |
| Reproducibility | 0,001 g |
| Linearity | ± 0,003 g |
| Readability moisture [d] (%) | 0,001% |
| Drying modes | Standard drying, Rapid drying, Gentle drying, Drying in levels |
| Switch-off criteria | time controlled, automatic, manual |
| Input voltage device / power [Max] | 230 V AC, 50 Hz |
High-precision moisture analyzer for demanding analyses, particularly suitable for plastic granulate
Technical Data
| Weighing capacity [Max] | 50 g |
| Readability [d] | 0,1 mg |
| Weighing system | Force compensation |
| Sample – Moisture content | 0,001% - 100% |
| Sample – Dry content | 100% - 0,001% |
| Temperature range (in steps up to) | 30 °C - 175 °C (1 °C) |
| Stabilization time | 4 s |
| Units | g, % Humidity, % Dry mass, % ATRO |
| Reproducibility | 0,0001 g |
| Linearity | ± 0,0003 g |
| Readability moisture [d] (%) | 0,0001% |
| Drying modes | Standard drying, Rapid drying, Gentle drying, Drying in levels |
| Switch-off criteria | time controlled, automatic, manual |
| Input voltage device / power [Max] | 230 V AC, 50 Hz |
Moisture analyzer with intuitive graphic display and moisture measurement up to 0,001%
Technical Data
| Weighing capacity [Max] | 60 g |
| Readability [d] | 0,1 mg |
| Weighing system | Force compensation |
| Sample – Moisture content | 0,01% - 100% |
| Sample – Dry content | 100% - 0,01% |
| Temperature range (in steps up to) | 35 °C - 160 °C (1 °C) |
| Stabilization time | 4 s |
| Units | g, mg, % rH, % Dry mass |
| Reproducibility | 0,1 mg |
| Linearity | ± 0,6 mg |
| Readability moisture [d] (%) | 0,001% |
| Drying modes | Standard drying, Rapid drying |
| Switch-off criteria | time controlled, automatic, manual |