5 x ABT-A02 Protective working cover for Analytical balance KERN ABT
Prices drop
Weighing capacity [Max] | 320 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232 standard, USB-Device |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 300 g (E2) |
Ambient temperature | 10 °C – 30 °C |
Dimensions weighing surface (Ø) | 91 mm |
Material draught shield | glass |
Material housing | plastic |
Dimension housing (W×D×H) | 213×333×338 mm |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
- Data interface RS-232
- Suitable for Analytical balance KERN ACS/ACJ, KERN ABS-N/ABJ-NM
5 x KERN ACS-A02 Protective working cover for KERN ABS-N and ABJ-NM
Analytical balance with flexible functionality and touch display
Weighing capacity [Max] | 120 g |
Readability [d] | 0,1 mg |
Units | g, mg, gn, dwt, tl (Tw), ozt, ct, lb, oz, ffa |
Linearity | ± 0,3 mg |
Reproducibility | 0,3 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232 standard, USB-Device |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 100 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Weighing capacity [Max] | 220 g |
Readability [d] | 0,1 mg |
Units | g, mg, gn, dwt, tl (Tw), ozt, ct, lb, oz, ffa |
Linearity | ± 0,3 mg |
Reproducibility | 0,3 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232 standard, USB-Device |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 200 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Weighing capacity [Max] | 320 g |
Readability [d] | 0,1 mg |
Units | g, mg, gn, dwt, tl (Tw), ozt, ct, lb, oz, ffa |
Linearity | ± 0,4 mg |
Reproducibility | 0,4 mg |
Stabilization time | 5 s |
Tolerance weighing | |
Interfaces | RS-232 standard, USB-Device |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 300 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Technical Data KERN ADT 100-4
Weighing capacity [Max] | 120 g |
Readability [d] | 0,1 mg |
Units | kg, g, mg, gn, dwt, tl (Tw), ozt, ct, lb, N, oz, ffa |
Linearity | ± 0,3 mg |
Reproducibility | 0,3 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232, USB-Device |
Adjustment | Internal calibration (automatic) |
Recommended adjusting weight | 100 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Technical Data KERN ADT 200-4
Weighing capacity [Max] | 220 g |
Readability [d] | 0,1 mg |
Units | kg, g, mg, gn, dwt, tl (Tw), ozt, ct, lb, N, oz, ffa |
Linearity | ± 0,3 mg |
Reproducibility | 0,3 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232, USB-Device |
Adjustment | Internal calibration (automatic) |
Recommended adjusting weight | 200 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Technical Data KERN ADT 300-4
Weighing capacity [Max] | 320 g |
Readability [d] | 0,1 mg |
Units | kg, g, mg, gn, dwt, tl (Tw), ozt, ct, lb, N, oz, ffa |
Linearity | ± 0,4 mg |
Reproducibility | 0,4 mg |
Stabilization time | 5 s |
Tolerance weighing | |
Interfaces | RS-232, USB-Device |
Adjustment | Internal calibration (automatic) |
Recommended adjusting weight | 300 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
5 x KERN ALJ-A01 Protective working cover for analytical balance and moisture analyser
ioniser to neutralise electrostatic charge for fixed installation in the analytical balance. This it makes for convenient handling as you no longer need a separate device. Simply enable the ioniser fan at the push of a button
- Is fitted in place of the existing glass rear panel of the draft shield
- Please order at the time you order your balance
- Scope of delivery: rear panel, ioniser, power supply
- Protective working cover over keypad
- Similar to illustration
- 5 items
Compact analytical balance with internal adjustment
Technical Data KERN AXE 100-4
Weighing capacity [Max] | 120 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct, oz |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Interfaces | RS-232 standard |
Adjustment options | Internal calibration (automatic) |
Recommended adjusting weight | 100 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 80 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Dimension housing (W×D×H) | 195×300×295 mm |
Material weighing plate | stainless steel |
Net weight approx. | 5,0 kg |
Compact analytical balance with internal adjustment
Technical Data KERN AXE 200-4
Weighing capacity [Max] | 220 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct, oz |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Interfaces | RS-232 standard |
Adjustment options | Internal calibration (automatic) |
Recommended adjusting weight | 200 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 80 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Dimension housing (W×D×H) | 195×300×295 mm |
Material weighing plate | stainless steel |
Net weight approx. | 5,0 kg |
Compact analytical balance with simple and convenient 5-key operation
Technical Data KERN AXS 100-4
Weighing capacity [Max] | 120 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct, oz |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Interfaces | RS-232 standard |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 100 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 80 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Dimension housing (W×D×H) | 195×300×295 mm |
Material weighing plate | stainless steel |
Net weight approx. | 5,0 kg |
Compact analytical balance with simple and convenient 5-key operation
Technical Data KERN AXS 200-4
Weighing capacity [Max] | 220 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct, oz |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Interfaces | RS-232 standard |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 200 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 80 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Dimension housing (W×D×H) | 195×300×295 mm |
Material weighing plate | stainless steel |
Net weight approx. | 5,0 kg |
KERN BFB-A03 Cable with special length 15 m, between display device and platform, must be ordered at purchase