- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
Prices drop
Active filters
- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
Measuring System
Measuring range torque [Max] 1 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 10 Nm
characteristic value - nominal 1,2 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 10 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 100 Nm
characteristic value - nominal 1,9 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 20 Nm
characteristic value - nominal 1,3 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 20 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 200 Nm
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 0,2 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 5 Nm
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 50 Nm
characteristic value - nominal 1,7 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 50 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 500 Nm
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
- Easy to clean surface
- Protection class IP 65
- Weighing platform divided into two parts
- Functions: Weighing, taring, hold
- Energy-saving auto-off function
Video microscope with bright image reproduction and intuitive operation
Technical Data
| Optical system | Axial |
| Tube type | Display |
| Magnification ratio | 6,4:1 |
| Zoom [Min] | 0,7x |
| Zoom [Max] | 4,5x |
| Illuminance | Reflected light |
| Illumination intensity incident light | 3 W |
| Illumination type incident light | LED |
| Focusing mechanism | coarse drive |