- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
Prices drop
Active filters
Measuring System
Measuring range torque [Max] 1 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 10 Nm
characteristic value - nominal 1,2 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 10 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 100 Nm
characteristic value - nominal 1,9 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 20 Nm
characteristic value - nominal 1,3 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 20 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 200 Nm
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 0,2 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 5 Nm
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 50 Nm
characteristic value - nominal 1,7 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 50 Nm
IP protection - complete device IP65
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,5 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
Measuring System
Measuring range torque [Max] 500 Nm
characteristic value - nominal 1,5 mV/V
characteristic value - variance 0,2 mV/V
connection 4-wire
Input resistance - nominal 380 Ω
Input resistance - variance 10 Ω
Output resistance - nominal 350 Ω
Output resistance - variance 3 Ω
Recommended exitation voltage [Min] 9 V
Recommended exitation voltage [Max] 12 V
Isolation resistance - [Min] 5000 MΩ
Combined error 0,5% Construction
Material steel
Cable length 2 m
Net weight approx. 0,40 kg
- Easy to clean surface
- Protection class IP 65
- Weighing platform divided into two parts
- Functions: Weighing, taring, hold
- Energy-saving auto-off function
Wheelchair platform scale with low overall height for easy access – with approval for professional, mobile medical use in medical diagnostics, verification optional
Technical Data
Weighing capacity [Max] | 300 kg; 400 kg |
Readability [d] | 100 g; 200 g |
Units | kg |
Interfaces | RS-232 standard |
Dimensions weighing platform (W×D×H) | 1255×1060×60 mm |
Battery operating time | 50 h |
Rechargeable battery operating time - backlight off | 45 h |
Display device cable length | 1,8 m |
Net weight | 42,2 kg |
Conformity assessment possible ex works | |
Approved as a medical device | |
Transport wheels | |
Construction type of the scale | Multi-division balance |