5 x ABT-A02 Protective working cover for Analytical balance KERN ABT
Prices drop
Weighing capacity [Max] | 320 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232 standard, USB-Device |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 300 g (E2) |
Ambient temperature | 10 °C – 30 °C |
Dimensions weighing surface (Ø) | 91 mm |
Material draught shield | glass |
Material housing | plastic |
Dimension housing (W×D×H) | 213×333×338 mm |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
- Data interface RS-232
- Suitable for Analytical balance KERN ACS/ACJ, KERN ABS-N/ABJ-NM
5 x KERN ACS-A02 Protective working cover for KERN ABS-N and ABJ-NM
Analytical balance with flexible functionality and touch display
Weighing capacity [Max] | 120 g |
Readability [d] | 0,1 mg |
Units | g, mg, gn, dwt, tl (Tw), ozt, ct, lb, oz, ffa |
Linearity | ± 0,3 mg |
Reproducibility | 0,3 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232 standard, USB-Device |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 100 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Weighing capacity [Max] | 220 g |
Readability [d] | 0,1 mg |
Units | g, mg, gn, dwt, tl (Tw), ozt, ct, lb, oz, ffa |
Linearity | ± 0,3 mg |
Reproducibility | 0,3 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232 standard, USB-Device |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 200 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Weighing capacity [Max] | 320 g |
Readability [d] | 0,1 mg |
Units | g, mg, gn, dwt, tl (Tw), ozt, ct, lb, oz, ffa |
Linearity | ± 0,4 mg |
Reproducibility | 0,4 mg |
Stabilization time | 5 s |
Tolerance weighing | |
Interfaces | RS-232 standard, USB-Device |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 300 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Technical Data KERN ADT 100-4
Weighing capacity [Max] | 120 g |
Readability [d] | 0,1 mg |
Units | kg, g, mg, gn, dwt, tl (Tw), ozt, ct, lb, N, oz, ffa |
Linearity | ± 0,3 mg |
Reproducibility | 0,3 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232, USB-Device |
Adjustment | Internal calibration (automatic) |
Recommended adjusting weight | 100 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Technical Data KERN ADT 200-4
Weighing capacity [Max] | 220 g |
Readability [d] | 0,1 mg |
Units | kg, g, mg, gn, dwt, tl (Tw), ozt, ct, lb, N, oz, ffa |
Linearity | ± 0,3 mg |
Reproducibility | 0,3 mg |
Stabilization time | 3 s |
Tolerance weighing | |
Interfaces | RS-232, USB-Device |
Adjustment | Internal calibration (automatic) |
Recommended adjusting weight | 200 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
Analytical balance with flexible functionality and touch display
Technical Data KERN ADT 300-4
Weighing capacity [Max] | 320 g |
Readability [d] | 0,1 mg |
Units | kg, g, mg, gn, dwt, tl (Tw), ozt, ct, lb, N, oz, ffa |
Linearity | ± 0,4 mg |
Reproducibility | 0,4 mg |
Stabilization time | 5 s |
Tolerance weighing | |
Interfaces | RS-232, USB-Device |
Adjustment | Internal calibration (automatic) |
Recommended adjusting weight | 300 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 90 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Material weighing plate | stainless steel |
Net weight approx. | 6 kg |
5 x KERN ALJ-A01 Protective working cover for analytical balance and moisture analyser
- Protective working cover over keypad
- Similar to illustration
- 5 items
Compact analytical balance with internal adjustment
Technical Data KERN AXE 100-4
Weighing capacity [Max] | 120 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct, oz |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Interfaces | RS-232 standard |
Adjustment options | Internal calibration (automatic) |
Recommended adjusting weight | 100 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 80 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Dimension housing (W×D×H) | 195×300×295 mm |
Material weighing plate | stainless steel |
Net weight approx. | 5,0 kg |
Compact analytical balance with internal adjustment
Technical Data KERN AXE 200-4
Weighing capacity [Max] | 220 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct, oz |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Interfaces | RS-232 standard |
Adjustment options | Internal calibration (automatic) |
Recommended adjusting weight | 200 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 80 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Dimension housing (W×D×H) | 195×300×295 mm |
Material weighing plate | stainless steel |
Net weight approx. | 5,0 kg |
Compact analytical balance with simple and convenient 5-key operation
Technical Data KERN AXS 100-4
Weighing capacity [Max] | 120 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct, oz |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Interfaces | RS-232 standard |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 100 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 80 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Dimension housing (W×D×H) | 195×300×295 mm |
Material weighing plate | stainless steel |
Net weight approx. | 5,0 kg |
Compact analytical balance with simple and convenient 5-key operation
Technical Data KERN AXS 200-4
Weighing capacity [Max] | 220 g |
Readability [d] | 0,1 mg |
Units | g, mg, ct, oz |
Linearity | ± 0,3 mg |
Reproducibility | 0,2 mg |
Stabilization time | 3 s |
Interfaces | RS-232 standard |
Adjustment options | Adjusting with external weight |
Recommended adjusting weight | 200 g (E2) |
Ambient temperature | 15 °C – 25 °C |
Dimensions weighing surface (Ø) | 80 mm |
Material draught shield | glass |
Material housing | ABS plastic |
Dimension housing (W×D×H) | 195×300×295 mm |
Material weighing plate | stainless steel |
Net weight approx. | 5,0 kg |
Height of stand approx. 1040 mm
Suitable for:
Weighing beams KERN UFA
Floor scales KERN BFB
KERN BFN and KERN BFS
Pallet scales KERN UFB and KERN UFN
Drive-through scale KERN NFB
- to connect an external device
- cable length approx. 1,5 m
Suitable for Floor scales KERN BFB and KERN BFS, counting scale KERN CFS,bench scale KERN GAB-N, platform scale KERN IFB, Display devices KERN KFB-TM and KERN KFN-TM, drive-through scale KERN NFB, precision balance KERN PFB, Pallet scales KERN UFB and KERN UFN and Weighing beams dimensions KERN UFA