Attachment rings for safe positioning of the SAUTER sensors
Prices drop
Active filters
Calibration foils for increased measuring accuracy (covers the range from 20 up to 2000 µm, with ˂ 3 % tolerance)
ATE 01 Sensor, Type F for SAUTER Digital coating thickness gauge
Type F: Coatings on steel and iron
fits for digital coating thickness gauge TG 1250-0.1FN
magnetic and non magnetic
- Ideal for transferring measuring data from the internal data memory of the measuring instrument to Microsoft Excel®
- Suitable for Coating thickness gauges SAUTER TC, SAUTER TE, SAUTER TF, SAUTER TG
- Hardness testing device SAUTER HD
- Sound level meter SAUTER SU
- Ultra-sound material thickness measuring device SAUTER TD-US, TN-US
- Compatible with following operating systems: Microsoft Windows 7, 8.1, 10®
- interface cable included
- External sensor, 2,5 MHz, Ø 14 mm
- for thick samples, in particular cast iron with rough upper surfaces: measuring range (steel) 3 - 300 mm
- External sensor, 7 MHz, Ø 6 mm
- For thin test materials: measuring range (steel) 0,75 - 80 mm
External sensor, 5 MHz, Ø 10 mm, transducer at an angle of 90°
External measuring head, 5 MHz, ∅ 10 mm, for echo-echo measuring
Suitable for Ultra-sound material thickness measuring device SAUTER TN-EE
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 100-3Q1
| Weighing capacity [Max] | 100 kg |
| Measuring range force [Max] (N) | 1 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M12 |
| Mounting - force dissipation | Threaded hole M12 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 1000-3Q1
| Weighing capacity [Max] | 1000 kg |
| Measuring range force [Max] (N) | 10 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M12 |
| Mounting - force dissipation | Threaded hole M12 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 150-3Q1
| Weighing capacity [Max] | 150 kg |
| Measuring range force [Max] (N) | 1.5 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M12 |
| Mounting - force dissipation | Threaded hole M12 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 1500-3Q1
| Weighing capacity [Max] | 1500 kg |
| Measuring range force [Max] (N) | 15 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M16 |
| Mounting - force dissipation | Threaded hole M16 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 200-3Q1
| Weighing capacity [Max] | 200 kg |
| Measuring range force [Max] (N) | 2 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M12 |
| Mounting - force dissipation | Threaded hole M12 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 2000-3Q1
| Weighing capacity [Max] | 2000 kg |
| Measuring range force [Max] (N) | 20 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M16 |
| Mounting - force dissipation | Threaded hole M16 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 300-3Q1
| Weighing capacity [Max] | 300 kg |
| Measuring range force [Max] (N) | 3 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M12 |
| Mounting - force dissipation | Threaded hole M12 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 3000-3Q1
| Weighing capacity [Max] | 3000 kg |
| Measuring range force [Max] (N) | 30 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M24 |
| Mounting - force dissipation | Threaded hole M24 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 50-3Q1
| Weighing capacity [Max] | 50 kg |
| Measuring range force [Max] (N) | 500 N |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M12 |
| Mounting - force dissipation | Threaded hole M12 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 500-3Q1
| Weighing capacity [Max] | 500 kg |
| Measuring range force [Max] (N) | 5 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M12 |
| Mounting - force dissipation | Threaded hole M12 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 5000-3Q1
| Weighing capacity [Max] | 5000 kg |
| Measuring range force [Max] (N) | 50 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M24 |
| Mounting - force dissipation | Threaded hole M24 |
6-wire "S" measuring cell made of nickel-plated steel for force and mass measurement
Technical Data SAUTER CS 6000-3Q1
| Weighing capacity [Max] | 6000 kg |
| Measuring range force [Max] (N) | 60 kN |
| Design | "S" shaped cell |
| Directions of force | tension, compression |
| Measuring applications | force, mass |
| Load cell - Combined error | 0,017% |
| Load cell OIML class | C3 |
| Load cell - Resolution (verifiable) | 3000 e |
| Load cell - Y-value | 10000 |
| Load cell - characteristic value - nominal | 2 mV/V |
| IP protection - complete device | IP67 |
| Material | steel, nickel-plated |
| Load cell connection | 6-wire |
| Cable length | 5 m |
| Mounting - force application | Threaded hole M24x2 |
| Mounting - force dissipation | Threaded hole M24x2 |
Ideal for torque testing of bottles and other packaging with screw tops
Convenient way to test the torque of tools
TECHNICAL DATA
| Measuring range torque [Max] (Nm) | 0,5 Nm |
| Readability torque [d] (Nm) | 0,1 mNm |
| Tolerance (% of [Max]) | 0,5% |
| Units | Nm, kgf/cm, kgf/m, in/lbs, ft/lbs |
| Supported torque pickups | 20 mm, 3/8 " |
| Overload protection (% of [Max]) | 120% |
| Memory function | |
| Internal data memory: Number of individual values | 500 |
| Peak function | |
| Limit-setting function | |
| Internal measuring frequency | 1000 Hz |
| Supplied power supply | Battery & Power supply |
| Battery / accumulator type | NiMH |
| Rechargeable battery operating time - backlight off | 18 h |
| Auto-off interval(s) in battery mode/rechargeable battery mode | 1 - 60 min |
| Interfaces | RS-232 standard, USB-Device |
| Display type | LCD graphic |
| Display resolution | 128×64 |
| Material housing | metal, lacquered |
| Dimension (W×D×H) | 200×100×50 mm |