Set complete with: motorised test stand SAUTER TVM 10KN120N, digital length measuring device LB, interface cable, data transfer software AFH FD, two interface converters AFH 12 and holder for SAUTER FH series force gauges
With digital length measuring device LB for creating force-displacement diagrams on the PC, maximum measuring range 300 mm, readability 0,01 mm
Technical Data SAUTER TVM 10KN120N
Generated force [Max] | 10 kN |
Traverse distance [Max] | 210 mm |
Type of drive | Electric motor |
Length measuring device | Length measuring device with display |
Input voltage power supply / power [Max] | 220 V AC, 50 Hz |
Limit switch | |
Repeat function | |
Speed display | |
Material housing | metal, lacquered |
Dimensions completely mounted (W×D×H) | 400×256×1535 mm |
Transversal movement speed [Min] | 30 mm/min |
Transversal movement speed [Max] | 120 mm/min |
Measurement alignment | vertical |
Set complete with: motorised test stand SAUTER TVM 20KN120N, digital length measuring device LB, interface cable, data transfer software AFH FD, two interface converters AFH 12 and holder for SAUTER FH series force gauges
With digital length measuring device LB for creating force-displacement diagrams on the PC, maximum measuring range 300 mm, readability 0,01 mm
Technical Data SAUTER TVM 10KN120N
Generated force [Max] | 20 kN |
Traverse distance [Max] | 210 mm |
Type of drive | Electric motor |
Length measuring device | Length measuring device with display |
Input voltage power supply / power [Max] | 220 V AC, 50 Hz |
Limit switch | |
Repeat function | |
Speed display | |
Material housing | metal, lacquered |
Dimensions completely mounted (W×D×H) | 400×256×1535 mm |
Transversal movement speed [Min] | 30 mm/min |
Transversal movement speed [Max] | 120 mm/min |
Measurement alignment | vertical |
Set complete with: motorised test stand SAUTER TVM 5000N230N, digital length measuring device LB, interface cable, data transfer software AFH FD, two interface converters AFH 12 and holder for SAUTER FH series force gauges
With digital length measuring device LB for creating force-displacement diagrams on the PC, maximum measuring range 300 mm, readability 0,01 mm
Technical Data SAUTER TVM 10KN120N
Generated force [Max] | 5 kN |
Traverse distance [Max] | 210 mm |
Type of drive | Electric motor |
Length measuring device | Length measuring device with display |
Input voltage power supply / power [Max] | 220 V AC, 50 Hz |
Limit switch | |
Repeat function | |
Speed display | |
Material housing | metal, lacquered |
Dimensions completely mounted (W×D×H) | 400×256×1035 mm |
Transversal movement speed [Min] | 10 mm/min |
Transversal movement speed [Max] | 230 mm/min |
Measurement alignment | vertical |
Set complete with: motorised test stand SAUTER TVM 5000N230NL, digital length measuring device LB, interface cable, data transfer software AFH FD, two interface converters AFH 12 and holder for SAUTER FH series force gauges
With digital length measuring device LB for creating force-displacement diagrams on the PC, maximum measuring range 300 mm, readability 0,01 mm
Technical Data SAUTER TVM 10KN120N
Generated force [Max] | 5 kN |
Traverse distance [Max] | 210 mm |
Type of drive | Electric motor |
Length measuring device | Length measuring device with display |
Input voltage power supply / power [Max] | 220 V AC, 50 Hz |
Limit switch | |
Repeat function | |
Speed display | |
Material housing | metal, lacquered |
Dimensions completely mounted (W×D×H) | 400×256×1535 mm |
Transversal movement speed [Min] | 10 mm/min |
Transversal movement speed [Max] | 230 mm/min |
Measurement alignment | vertical |
Practical set for force-displacement-measurements in laboratory and industry
Set includes:
- Premium motorised test stand SAUTER TVS 10KN100 up to 10 kN
- length measuring system LD
- interface cable
- data transfer software AFH LD
- interface converter AFH 12
- mounting for force gauge
Practical set for force-displacement-measurements in laboratory and industry
Set includes:
- Premium motorised test stand SAUTER TVS 20KN100 up to 20 kN
- length measuring system LD
- interface cable
- data transfer software AFH LD
- interface converter AFH 12
- mounting for force gauge
Practical set for force-displacement-measurements in laboratory and industry
Set includes:
- Premium motorised test stand SAUTER TVS 5000N240 up to 5 kN
- length measuring system LD
- interface cable
- data transfer software AFH LD
- interface converter AFH 12
- mounting for force gauge
Practical set for force-displacement-measurements in laboratory and industry
Technical Data SAUTER TVS 50KN80-LD
Generated force [Max] | 50 kN |
Traverse distance [Max] | 210 mm |
Type of drive | Stepper motor |
Length measuring device | Length measuring device with data interface |
Input voltage power supply / power [Max] | 230 V AC, 50 Hz |
Limit switch | |
Repeat function | |
Speed display | |
Material housing | metal, lacquered |
Dimensions completely mounted (W×D×H) | 480×255×1670 mm |
Transversal movement speed [Min] | 1 mm/min |
Transversal movement speed [Max] | 70 mm/min |
Set includes:
- Premium motorised test stand up to 50 kN
- length measuring system LD
- interface cable
- data transfer software AFH LD
- interface converter AFH 12
- mounting for force gauge
Calibrator for regular adjustment of the sound level meter, class 1, as well as testing the linearity of sound level meters
- - Applicable standards: IEC60942:2003 Class 1, ANSI S1.40-1984, GB/T 15173-1994.
- - Output frequency 1 kHz (+/- 0,5 %)
- - Output of acoustic pressure, can be selected at 94 dB or 114 dB (± 0.3 dB)
- - Distortion factor ˂ 2 %
- - Stabilisation time ˂ 10 s
- - Permissible ambient temperature range -10 °C/50 °C
- - The calibrator is designed for ½" as well as ¼" microphones (adapter included in the delivery) in accordance with the IEC 61094-4 standard
- - Battery operation, 2× 1.5 V AA, not standard, operating time up to 40 hours
- - Dimensions W×D×H 70×70×48 mm
- - Net weight approx. 137 g
Versatile sound level meter with calibration certificate
Main fields of application areas
- Workplace
- Transport
- Industry and assembly hall
- Automotive industry
Technical Data
Measuring range Sound | 30 dB – 130 dB |
Readability sound [d] (dB) | 0,1 dB |
Tolerance (% of [Max]) | 3% |
Units | dB |
Sound level measuring modes | Lp, Leq, Ln |
Sound level methods of evaluation | A, C, F |
Frequency range | 20 Hz – 12,5 kHz |
Memory function | |
Hold function | |
Peak function | |
Limit-setting function | |
Microphone sensitivity | 30 mV/Pa |
Battery | 4×1.5 V AAA |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 236×63×40 mm |
Test bench for round, flat objects for use with Ultrasound hardness testing device SAUTER HO-M
- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
- accuracy ≥ 4 HL
- Ø 90 mm (± 1 mm)
- Net weight approx. 2,7 kg
Material thickness pulse-echo [Max] (mm) | 600 mm |
Material thickness pulse-echo [Min] (mm) | 0,7 mm |
Material thickness echo-echo [Max] (mm) | 100 mm |
Material thickness echo-echo [Min] (mm) | 3 mm |
Measuring range pulse-echo | 0,7 mm – 600 mm |
Measuring range echo-echo | 3 mm – 100 mm |
Readability material thickness [d] (mm) | 0,01 mm |
Tolerance (% of [Max]) | 0,4% |
Units | mm, inch |
Speed of sound [Max] (m/s) | 19999 m/s |
Speed of sound [Min] (m/s) | 200 m/s |
Speed of sound | 200 m/s – 19999 m/s |
Measuring head measuring frequency | 5 MHz |
Battery | 2×1.5 V AA |
Memory function | |
Statistic function | |
Limit-setting function | |
Continuous capture possible | |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 31×69×130 mm |
Interfaces | USB-Device |
Cable length | 1 m |