fits for digital coating thickness gauge TG 1250-0.1FN
magnetic and non magnetic
Here you will find any scale for professional applications in industry, trade und retail. Regardless of where your business weighs in - you'll find the right scale at Scales and Measuring.
Scales and Machinery for catering and commercial food services
In the "Medical scales and measuring devices" category, we offer a wide range of high-quality and precise medical measuring instruments for clinics, doctor's practices, care facilities and veterinarians. These specialized devices are designed to carry out precise measurements and weight determinations in a medical context and thus contribute to the precise diagnosis, therapy and care of patients.
Our selection includes different types of medical scales that meet the specific requirements of different medical disciplines. These include body scales for determining patient weight, baby scales for precisely monitoring the growth of newborns, and animal scales for veterinary applications. These scales are carefully calibrated to ensure high accuracy and reliability.
In addition to scales, we offer a variety of other medical devices, including blood pressure monitors, pulse and oxygen monitors, and body temperature monitors. These instruments enable comprehensive monitoring of patients' vital parameters and thus support preventive medicine and the early detection of health problems.
Our products come from renowned manufacturers who adhere to the highest quality standards. They are ergonomically designed and easy to use, ensuring smooth integration into clinical or veterinary workflow. In addition, many of our medical devices are equipped with modern interfaces that enable seamless integration into digital health records and other information systems.
Trust our medical scales and devices to take precise measurements and create a reliable basis for medical decisions. With our extensive range, we support healthcare providers in ensuring optimal patient care and increasing the efficiency of their work processes.
For centuries now, weight pieces have been used in scales for weighing procedures. This original purpose has now almost disappeared. Today, weights are used almost exclusively for adjusting and testing = calibration of electronic balances. They are now named “test weights” as this is their contemporary purpose.
Adjusting a balance means that you are intervening in the weighing system, to make sure that the display is set to show the correct nominal value.
With calibration on the other hand, there is no intervention, you are testing whether the display is correct and documenting any deviation.
The internationally valid OIML norm R111:2004 classifies test weights hierarchically in accuracy classes, where E1 is the most accurate and M3 is the least accurate weight class. With KERN you get the whole test weight range in all OIML accuracy classes E1, E2, F1, F2, M1, M2, M3.
As the test weight only becomes an ISO 9000ff-compliant test instrument when its accuracy has been proven, we offer the appropriate DAkkS Calibration certificate or verification certificate (in connection with a box) for all KERN test weights. For further details see chapter DAkkS Calibration Service.
We offers you the appropriate test weight package for your balance, consisting of the test weight, box and DAkkS-calibration certificate, as proof of its accuracy. The best prerequisite for a correct adjustment or checking of your scales.
Classes of accuracy of test weights E, F, M and their general relation to the types of balances:
Test weights for customers who require a high degree of accuracy for the most demanding applications. For high-resolution balances with d > 1,000,000 Use recommended with DAkkS calibration certificate only.
Most accurate test weights for high resolution analytical balances of verification class I ≥ 100,000 e
Test weights for analytical balances/precision balances for verification class I/II ≤ 100,000 e
Test weights for precision balances of verification class II ≤ 30,000 e
Test weights for industrial and commercial scales of verification class III ≤ 10,000 e
The appropriate test weight for your new KERN balance can also be found directly in the accessories of the balance in our webshop.
To protect your test weights we can offer you an appropriate weight case. If there are no legal or normative specifications, then you have the choice between plastic, aluminium protected or wood. The available weight cases are shown as a symbol in the test weight tables on the following pages. This way you have all the materials, versions, sizes and prices at a glance, listed in a concise way.
A balance can never be more accurate than the test weight that is used to adjust it, it all depends on its tolerance. The accuracy of the test weight should correspond to the readout [d] of the balance, or rather be more precise.
Nominal weight value is shown in adjust mode “CAL” in the balance display. Given a choice, the heaviest weight is the most suitable for accurate measurement.
Once accuracy and nominal weight value are specified, the suitable test weight is selected according to the tolerances “Tol” of the indi vidual accuracy classes E2 – M3, see column “Tol ± mg” at the respective weight.
Balance with weighing range [Max] 2000 g = 2 kg and readout [d] = 0,01 g = 10 mg
Exception: analytical balances (readout [d] ≤ 0,1 mg): E1 test weights are recommended. Depending on the safety requirements, E2 test weights with a DAkkS calibration certificate will also be sufficient.
The key points from the OIML norm R111:2004 OIML (Organisation Internationale de Métrologie Légale) has established the exact metrological requirements for weights in verified applications in approx. 100 states all over the world. The OIML recommendation R111 (2004 Edition) for weights relates to sizes 1 mg – 5000 kg. Statements are made on the accuracy, materials, geometric shape, marking and storage of the weights.
The error limit classes are in fixed hierarchical levels in the proportion of 1:3, where E1 is the most accurate and M3 is the least accurate weight class. When testing weights with other weights, the correct test class is the next highest class.
Error limit classes (= tolerances)
The values given in the table below (tolerances ± ... mg) are the respective permitted fabrication tolerances. They are to be equal to the measuring uncertainty of the weight, if no DAkkS calibration certificate is available.
The problem is the air buoyancy, which makes the weight appear lighter. In order to avoid this “distortion” in daily use, all weights are adjusted to the unit specifications as given in R111, e.g. it is accepted that: material density of the weights is 8000 kg/m3, air density is 1.2 kg/m3 and measuring temperature is 20 °C.
Our test weights: Unless otherwise specified, they conform to OIML R111:2004 in every detail.
and much more
Measurement technology for industry, laboratories and quality assurance
Accessories
Offers and discontinued models
fits for digital coating thickness gauge TG 1250-0.1FN
magnetic and non magnetic
Ultrasound contact gel, approx. 60 ml
Price 100 ml = 50,00 €
Reliable material thickness gauge for daily use
TB 200-0.1US-RED Can only analyse these materials: cast iron, aluminium, copper, brass, zinc, quartz glass, polyehylene, PVC, grey cast iron, nodular cast iron, steel
Material thickness pulse-echo [Max] (mm) | 200 mm |
Material thickness pulse-echo [Min] (mm) | 1,5 mm |
Measuring range pulse-echo | 1,5 mm – 200 mm |
Measuring range echo-echo | – |
Readability material thickness [d] (mm) | 0,1 mm |
Tolerance (% of [Max]) | 0,5% |
Units | mm, inch |
Speed of sound [Max] (m/s) | 9999 m/s |
Speed of sound [Min] (m/s) | 500 m/s |
Speed of sound | 500 m/s – 9999 m/s |
Measuring head measuring frequency | 5 MHz |
Battery | 4×1.5 V AA |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 161×68×32 mm |
Cable length | 0,9 m |
Ultrasonic thickness gauge with external sensor
Material thickness pulse-echo [Max] (mm) | 225 mm |
Material thickness pulse-echo [Min] (mm) | 1,2 mm |
Measuring range pulse-echo | 1,2 mm – 225 mm |
Measuring range echo-echo | – |
Readability material thickness [d] (mm) | 0,1 mm |
Tolerance (% of [Max]) | 0,5% |
Units | mm, inch |
Speed of sound [Max] (m/s) | 9999 m/s |
Speed of sound [Min] (m/s) | 1000 m/s |
Speed of sound | 1000 m/s – 9999 m/s |
Measuring head measuring frequency | 5 MHz |
Battery | 4×1.5 V AAA |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 30×65×120 mm |
Cable length | 0,9 m |
External sensor, 5 MHz, Ø 10 mm, transducer at an angle of 90°
Hand-held measuring device for ultrasonic material thickness testing in Echo-Echo principle
Material thickness pulse-echo [Max] (mm) | 600 mm |
Material thickness pulse-echo [Min] (mm) | 0,65 mm |
Material thickness echo-echo [Max] (mm) | 30 mm |
Material thickness echo-echo [Min] (mm) | 3 mm |
Measuring range pulse-echo | 0,65 mm – 600 mm |
Measuring range echo-echo | 3 mm – 30 mm |
Readability material thickness [d] (mm) | 0,01 mm |
Tolerance (% of [Max]) | 0,5% |
Units | mm, inch |
Speed of sound [Max] (m/s) | 9999 m/s |
Speed of sound [Min] (m/s) | 1000 m/s |
Speed of sound | 1000 m/s – 9999 m/s |
Measuring head measuring frequency | 5 MHz |
Battery | 2×1.5 V AA |
Memory function | |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 150×74×32 mm |
Interfaces | USB-Device |
Cable length | 0,9 m |
Hand-held measuring device for ultrasonic material thickness testing in Echo-Echo principle
Material thickness pulse-echo [Max] (mm) | 600 mm |
Material thickness pulse-echo [Min] (mm) | 0,7 mm |
Material thickness echo-echo [Max] (mm) | 60 mm |
Material thickness echo-echo [Min] (mm) | 3 mm |
Measuring range pulse-echo | 0,7 mm – 600 mm |
Measuring range echo-echo | 3 mm – 60 mm |
Readability material thickness [d] (mm) | 0,01 mm |
Tolerance (% of [Max]) | 0,5% |
Units | mm, inch |
Speed of sound [Max] (m/s) | 9999 m/s |
Speed of sound [Min] (m/s) | 1000 m/s |
Speed of sound | 1000 m/s – 9999 m/s |
Measuring head measuring frequency | 5 MHz |
Battery | 2×1.5 V AA |
Memory function | |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 150×74×32 mm |
Interfaces | USB-Device |
Cable length | 0,9 m |
Door tester: Handle (length: 300 mm) and two round force receptor plates (∅ 85 mm) as an option to FH 1K up to FH 5K for the safe testing of clamping forces (not approved to DIN 18650 or similar), up to 5 kN
Accessories only (without device and cell)
With this attachments for tensile strength testing, the SAUTER FK can become a tensiometer for testing the material tension characteristics of cables, threads, wires, twine etc
Tensiometer attachment with Safe-insert function: Pull and release to insert the running cable in between the rolls
Suitable for force gauge KERN FK (models SAUTER FK 10. to SAUTER FK 250.)
Force-measuring device is not included with the delivery
AFK 02 Stainless steel handle bar with rubber grip for safe handling
Robust, digital force gauge for tensile and compressive force measurements
Measuring range force [Max] (N) | 10 N |
Readability force [d] (N) | 0,005 N |
Tolerance (% of [Max]) | 0,5% |
Measuring head measuring frequency | 1000 Hz |
Thread | M8 |
Supplied power supply | Power supply & battery included |
Hold function | |
Peak function | |
Measuring units: | N, lbf, kg, ozf |
Universal digital force gauge with graphics display and integrated measuring cell
Measuring range force [Max] (N) | 5 N |
Readability force [d] (N) | 0,002 N |
Tolerance (% of [Max]) | 0,2% |
Measuring head measuring frequency | 1000 Hz |
Number of platforms / channels | 1 |
Supplied power supply | Accu & Power supply |
Rechargeable battery | 4,8 V 750 mA |
Memory function | |
Limit-setting function | |
Hold function | |
Peak function | |
Material housing | metal, lacquered |
Dimensions completely mounted (W×D×H) | 215×75×30 mm |
Net weight approx. | 0,55 kg |
Interfaces | RS-232 standard, USB-Device, analogue (0 +/-2V) |
Portable measuring device for ultrasonic material thickness testing
Material thickness pulse-echo [Max] (mm) | 80 mm |
Material thickness pulse-echo [Min] (mm) | 0,75 mm |
Measuring range pulse-echo | 0,75 mm – 80 mm |
Measuring range echo-echo | – |
Readability material thickness [d] (mm) | 0,1 mm |
Tolerance (% of [Max]) | 0,5% |
Units | mm, inch |
Speed of sound [Max] (m/s) | 9999 m/s |
Speed of sound [Min] (m/s) | 1000 m/s |
Speed of sound | 1000 m/s – 9999 m/s |
Measuring head measuring frequency | 7 MHz |
Battery | 2×1.5 V AA |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 150×74×32 mm |
Cable length | 0,9 m |
Portable measuring device for ultrasonic material thickness testing
Material thickness pulse-echo [Max] (mm) | 230 mm |
Material thickness pulse-echo [Min] (mm) | 1,2 mm |
Measuring range pulse-echo | 1,2 mm – 230 mm |
Measuring range echo-echo | – |
Readability material thickness [d] (mm) | 0,1 mm |
Tolerance (% of [Max]) | 0,5% |
Units | mm, inch |
Speed of sound [Max] (m/s) | 9999 m/s |
Speed of sound [Min] (m/s) | 1000 m/s |
Speed of sound | 1000 m/s – 9999 m/s |
Measuring head measuring frequency | 5 MHz |
Battery | 2×1.5 V AA |
Material housing | plastic |
Dimensions completely mounted (W×D×H) | 150×74×32 mm |
Cable length | 0,9 m |
Manual test stand for highly accurate tensile and compressive force measurements, with length measurement
Generated force [Max] | 1 kN |
Traverse distance [Max] | 230 mm |
Type of drive | manual crank handle |
Length measuring device | Length measuring device with display |
Material housing | metal, lacquered |
Dimensions completely mounted (W×D×H) | 151×234×465 mm |
Travel distance per knob rotation (stroke per one turn) | 3 mm |
Test stand with electric motor for standard measurements
Generated force [Max] | 10 kN |
Traverse distance [Max] | 210 mm |
Type of drive | Electric motor |
Length measuring device | Length measuring device with display |
Input voltage power supply / power [Max] | 220 V AC, 50 Hz |
Limit switch | |
Repeat function | |
Speed display | |
Material housing | metal, lacquered |
Dimensions completely mounted (W×D×H) | 400×256×1535 mm |
Transversal movement speed [Min] | 30 mm/min |
Transversal movement speed [Max] | 120 mm/min |
Measurement alignment | vertical |
Premium test stand in table-top version – with precise step motor
Generated force [Max] | 500 N |
Traverse distance [Max] | 270 mm |
Type of drive | Stepper motor |
Input voltage power supply / power [Max] | 230 V AC, 50 Hz |
Limit switch | |
Repeat function | |
Speed display | |
Material housing | metal, lacquered |
Dimensions completely mounted (W×D×H) | 570×428×236 mm |
Transversal movement speed [Min] | 1 mm/min |
Transversal movement speed [Max] | 500 mm/min |
Measurement alignment | vertical |